TAS Portal
Wednesday scoring decision · 27 October 2026

Recommended snore formula

Recommend the later background-relative formula with the clamp.

More snoring-episode time raises the score. Louder snores relative to background add a small weight. Recording length sets the share; the provisional cap sets where the display reaches 100.

100 × √(clamp(Pw, 0, 82.5) / 82.5). The cap is provisional; input and device validation remain required.

Formulas · UI comparison · Evidence

What needs approval

  1. The recommended candidate.Episode duration weighted by sound above background, with the clamped square-root display.
  2. Parameters and fallback.Confirm weights 1.0 / 1.1 / 1.2, the 8 / 18 dB relative boundaries, the provisional 82.5 cap, quality rules and missing-noise behavior.
  3. Validation before release.Use compatible recordings and supported phones. Keep breathing highlights separate.

The workbook lacks this candidate’s required inputs. Its empty comparison card is not a zero score. 80/20 remains a historical comparator.

How the four formulas work

Read each row from left to right: what gets counted → how loudness matters → what gets displayed.

  1. 0180/20 blendCountWhole episode timeWeight80% time score + 20% loudness scoreDisplayBlended score
    S80/20=0.8A+0.2BS_{80/20}=0.8A+0.2B
    A=100min(E,75)75A=100\sqrt{\frac{\min(E,75)}{75}}
    B=clamp(100(L1−55)25,0,100)B=\operatorname{clamp}\!\left(\frac{100(L_1-55)}{25},0,100\right)

    E is episode-time share in percentage points. L₁ is the supplied sustained sound level.

  2. 02Weighted durationCountSnore-only timeWeightLight ×1 · medium ×2 · high ×4DisplayDirect weighted points
    W=100dL+2dM+4dH4TuW=100\frac{d_L+2d_M+4d_H}{4T_u}

    dL, dM and dH are snore durations in the sheet’s light, medium and high groups. Tᵤ is usable recording time; all durations use the same units.

  3. 03Weighted duration, curvedCountSame snore-only timeWeightSame ×1 / ×2 / ×4 weightsDisplaySquare-root scale + cap
    Scurve=100min(W,C)CS_{\mathrm{curve}}=100\sqrt{\frac{\min(W,C)}{C}}

    C ≈ 10.165721 percentage points, the supplied cohort’s 95th percentile. W and C use the same percentage-point scale.

  4. 04Later background-relative formula · recommendedCountWhole episode timeWeightMean snore weight: ×1 / ×1.1 / ×1.2DisplaySquare-root scale + cap
    Srelative=100clamp(Pw,0,82.5)82.5S_{\mathrm{relative}}=100\sqrt{\frac{\operatorname{clamp}(P_w,0,82.5)}{82.5}}
    Pw=100Tr∑jEjw¯jP_w=\frac{100}{T_r}\sum_j E_j\bar{w}_j

    Eⱼ is an episode’s duration; Tᵣ is recorded audio time. The mean weight w̄ⱼ is duration-weighted across its snores, using 1.0 / 1.1 / 1.2 at the 8 / 18 dB background-relative boundaries. The source defaults to 1.0 if an episode has no snore duration. Its missing-input policy and 82.5 cap still need approval.

Whole episodes can include quiet gaps. The two weighted-duration options use the same inputs; the curved version changes the display. The later formula uses sound above background noise, so its bands are not interchangeable with the sheet’s sound-level bands.

Explore the score

Adjust the recommended formula, or choose a measured comparison.

Try the recommended formula

Hypothetical inputs. One relative sound level applies to all episodes.

82.5% is provisional, not an approved cutoff. Moving it changes this illustration only.

A larger score is not a more accurate formula

Separate medians from 145 sleep-study records, not one person’s night. Each formula has its own score scale.

Score points (0–100) · Ring scale: 0–100

80/20 blend

Study median · 0–100 points

Weighted duration

Study median · 0–100 points

Weighted duration, curved

Study median · 0–100 points

Later background-relative formula · recommended

Missing compatible inputs

Showing study medians.

Original V1 report screen and source

Current V1 report from the source prototype. The cards above use the comparison dataset.

Original source UI; sample results are not the study medians above. Open original report ↗

Adapted from ScoreSummary, ScoreRing and the shared theme at source version 2703b2f. Card shape, spacing, ring geometry and color interpolation are reused. Formula names and dataset values are review-only substitutions; the source application is unchanged.

How much confidence should we have?

The sheet has 145 sleep-study records and 13 phone recordings from five people. The phone checks cover just one same-night pair and one person's seven nights.

That is useful early evidence. It is too limited to establish reliability across users and phones, or medical accuracy. The formulas also count snoring time differently, so their results do not isolate the effect of weighting alone.

Details for review

Open the evidence or calculation only when you need it.

Results, trade-offs and evidence limits

The two definitions also differ numerically: episode-time share has a PSG median of 33.56%, versus 13.03% for summed snore duration. The median within-record ratio is 2.47×.

Values below reproduce the workbook at its saved default settings. The phone evidence is one paired same-night session and seven nights from one person. Night-to-night variation includes real changes, not just measurement error.

Check80/20 ring1/2/4 linear1/2/4 √
PSG median (points)63.124.3365.23
Cohort SD / seven-night SD · higher favored3.822.072.14
Same-night phone gap / cohort SD · lower favored0.3000.6770.708
+6 dB mean movement / cohort SD · lower favored0.2240.6280.381
−6 dB mean movement / cohort SD · lower favored0.2230.2640.208

The old ring is favored on three of the four stability checks. The square-root version moves least in the quieter-level test. Raw point gaps are not comparable across these scales, so movement is divided by each formula's PSG cohort SD.

Cohort spread is not a clinical reference standard. The ±6 dB test shifts existing levels while keeping segmentation fixed; it is not a new phone recording or a background-noise test. PSG levels were shifted about +96.58 dB to place their median on the phone scale. The sheet cannot validate absolute loudness calibration.

Formula trade-offs

FormulaEvidence summaryTrade-off and decision
Historical 80/20 ringBest of the sheet’s three formulas on most normalized stability checks.Less direct meaning than a percentage. Uses a 75% duration cap and a 55–80 level scale; PSG level placement is uncalibrated. This is the sheet's October 13 baseline, not the later formula.
1/2/4 weighted time · linearThe direct scale shows weighted time without a display curve.Numerically low in this cohort. Hard 65/71 level boundaries amplify gain changes; these are not proven physical-loudness or severity boundaries.
1/2/4 weighted time · square rootIts cohort median rises from 4.33 to 65.23; the input is unchanged.Re-scales the linear measure rather than adding information. The p95 cap is cohort-derived; eight of 145 records tie at 100. A larger-looking score is not stronger evidence.
Later 1.0/1.1/1.2 relative-noise candidateThe smaller loudness weights use sound above background noise.Not computable fairly from this sheet: per-episode spans, snore weights and noise-floor inputs are missing. Its 82.5% cap is provisional. Run it on compatible inputs before claiming it wins.

See the typeset equations above.

Breathing-pause results and their limits

Two historical mappings

The sheet counts cycles at confidence ≥0.159 and fills thirds at 5, 10 and 30 cycles/hour. The later pinned source records knots at 0, 5, 15, 30 and 45, mapped to 0, 25, 50, 75 and 100 points. These mappings are different and are not approved clinical severity rules.

The current beta direction keeps high-confidence breathing highlights separate from the snore score. Earlier 50/50 and 30/70 combined formulas remain research; the accepted snore counts and frozen normalization references needed for them are not in this sheet.

Why the accuracy figures need restraint

The sheet's pooled pause/AHI rank correlation is 0.722, with AUC 0.894 at AHI≥15 and 0.855 at AHI≥30. However, 117 of its 145 records were used to fit the pause model. The held-out 28-record results are absent.

These reproduced figures are optimistic development context. They do not establish independent diagnostic performance, clinical cutoffs or a care trigger.

Source data and verification

Source: snore-and-pause-scoring 2.numbers, built 13 October 2026. Review version: 2026-10-27-score-tradeoffs-v1. The source contains 145 PSG records marked clean and 13 phone recordings from five people.

All 474 cached snore-score outputs and 33 comparison aggregates were independently reproduced, along with the histogram durations, ±6 dB outputs and pause-count mappings. The source file is unchanged. No fresh detector validation, audio measurement, random-error ranking simulation or tier sweep was performed.

Linked Notion tickets may require separate access. A successful page response does not confirm permission to view a ticket.

Related decisions: EAS-2 · formula, EAS-83 · inputs, EAS-30 · repeatability. Aggregate results and source digest.