← Atenvia planning · Baseline findings
Atenvia referral-to-result product spec
Initial desk baseline · 12 November 2026
Technical and product baseline pack, version 2026-11-12-atenvia-baseline-v1, records the source/branch inventory, bounded local build checks, current/reported/proposed data flows, product conflicts, measurement definitions and next validation needs. The desk review is available now; the proposed 27 November stakeholder/source-owner review remains open. No application code, live integration or infrastructure was changed. The planning schedule and scope remain as stated below.
Current discovery and planning scope · 11 November 2026
Version: 2026-11-12-atenvia-timeline-v4. The workshops, discovery and planning timeline reflects Shane’s direction to move the initial plan back one week. Timeline review is 24 November, product-definition review is 7 December and the initial planning review is 11 December. Plan against 8 Atenvia days/month each for Shane and Raena after reserving 15–20% of their 10-day allocations for the Snoraire handover. Kedar has limited involvement; stakeholder availability is assumed. The capacity-based recommendation adds a first planning baseline by 18 December and a planning/handover review by 15 January, with holiday allowance; this endpoint is proposed, not committed. Recommend one substantive external workshop per week, subject to bookings. Easmed should secure build resources during discovery. The exact IMDA requirements remain to be confirmed.
Our scope is workshopping, product discovery, technical discovery and planning. In parallel, we recommend that Easmed secure additional resources for building. This engagement includes no MVP implementation, connector development, deployment or pilot operation. The prior December–February delivery schedule is withdrawn; a future team must separately estimate and plan any build.
Earlier implementation proposals below are historical wherever they conflict with this scope. Current counterparts: Notion product home (separate access may be required), EAS-89 (separate access may be required) and EAS-16 (separate access may be required).
Technical baseline first · 12 November 2026
The current plan starts with technical discovery and an initial current-state baseline during 19–27 November, before broader product workshops during 30 November–11 December. Output: architecture/data map, existing-asset evidence/reuse inventory, API specification/access gaps and prioritised risks/questions. This is a timeboxed planning review, not an MVP build or comprehensive engineering audit. See the API specification/access register for public, login-protected and vendor-requested documentation. Later planning reviews and capacity assumptions remain as described in the current timeline.
prisma CLOUD API evidence · 12 November 2026
API discovery update, version 2026-11-12-prisma-api-discovery-v1: guide access verified and vendor-offered synthetic demo path recorded. Tenant/API access, data coverage and production rights remain unverified. Prepare the required registration details with Easmed; no request or build is authorized by this evidence update. Current planning scope and dates are unchanged.
Pam discovery · 27 October 2026
Version: 2026-10-27-atenvia-discovery-v1. Current discovery record and Granola source (separate access may be required). This later, 15:42 meeting supplies findings absent from the earlier review. Evidence is an AI summary, not a full transcript or validated implementation.
The proposed first version is a Singapore-only B2B clinic workspace with role-based login, analytics/reporting and downloadable source reports. Zoho owns inbound patient onboarding; only confirmed patients flow into Atenvia. Clinic/location access replaces the older doctor-only assumption, subject to an approved permission matrix. Manual report request and TAS PDF upload is a viable proposed path while vendor API cost/access remains unresolved.
Scheduling is deferred during the Zoho Bookings migration. Internal alerts target TAS, not doctors. Patient sharing, device recommendations, patient login and other markets are outside the proposed V1. PDF parsing and multi-report aggregation remain research, without approved formulas or extraction proof. Zoho’s inbound authority does not revoke the separate Atenvia application database or approve general write-back.
We need Gary’s V1 sign-off and grant mapping, named clinical/privacy reviewers, clinic/patient matching and note-ownership rules, PDF/data-model feasibility and an authorized view-only AirView access receipt for Jonas. The 70% private-clinic adoption aspiration needs a denominator and period. Reconcile “next week” with the earlier post-Airese staffing plan before assigning capacity.
The September referral/booking build and earlier scheduling, doctor-notification and individual-doctor access assumptions below are historical proposals wherever they conflict with this discovery. Earlier summaries’ missing-outcome statements describe their retrieval coverage at the time. No ticket closure, accepted replacement criteria, API success, patient-safe pilot or launch approval follows from these notes.
Historical records and earlier proposals
Status: Draft for stakeholder confirmation
Version: 0.1
Date: 9 September 2026
Owner: Product
Meeting review · 27 October 2026
Version: 2026-10-27-atenvia-meetings-v1. The six-meeting review (internal working reference; not published) and portal update put the latest discovery sequence above the historical proposal. The same supplement was saved to the Notion product home (separate access may be required) and EAS-89 (separate access may be required). Raena and Kedar begin discovery with Pam; Shane transitions after Airese launches, then arranges kickoff with Audrey. Discovery outcomes, client mandate, release scope, dates and API/data-path receipts remain unverified. Ticket properties and acceptance criteria were not changed. The notes are AI summaries from Granola’s accessible 30-day window, without transcripts.
The access limitation in the earlier supplement below is historical. Current saved-text and layout verification is recorded in the meeting review.
Earlier discovery and staffing supplement · 27 October 2026
Supplement: 2026-10-27-completeness-v1. The 26 October evening meeting (separate access may be required) records an internal plan: Raena and Kedar begin discovery with Pam facilitating doctor access and vetting questions; Shane transitions to Atenvia after Airese MVP launch. Formal in-person kickoff follows launch, with Audrey attending. The 27 October discovery session was planned; its occurrence/results were not verified here.
At kickoff we need the client product owner and mandate, technical lead, sponsor, decision deadlines and agreed release scope. Ervin’s attendance or formal delegation to Gary remains to confirm. The referral-to-result slice below remains a draft for validation with clinicians and TAS operations. Airese launch is a staffing dependency for formal kickoff, without adding an Airese product integration. Mid-November/February references are planning assumptions, not approved launch dates.
Source coverage and remaining evidence (internal working reference; not published). The canonical Notion counterpart could not be identified/read in this session and remains unsynced.
1. Product decision
Atenvia’s first release will prove one business outcome: a referring clinician can send a patient to The Air Station (TAS), book the patient into TAS sleep-test capacity, and retrieve the resulting report without relying on a phone call or fragmented follow-up.
This is a build-neutral specification. The existing Atenvia prototype is reference material for patient-list, patient-detail and report presentation patterns; it is not the assumed implementation base.
2. Why this slice
The product exists to make referring to TAS easier and to give the referring clinician continuity after the referral. The first release should therefore prove the referral relationship before building long-term CPAP monitoring.
The release succeeds when:
- a clinician can complete the happy path from referral to result;
- TAS operations can fulfil that referral using its real operating process;
- access to patient information is correctly scoped and auditable;
- a clinic confirms that the workflow saves effort or removes a coordination step;
- the result can be delivered using a manual PDF workflow, without waiting for vendor APIs.
3. Explicit non-goals
The first release will not include:
- live CPAP compliance feeds;
- AirView, PrismaCloud, CloudPAT or NeXus360 integration;
- automated diagnosis or treatment recommendations;
- management of a clinician’s own calendar;
- a patient-facing portal or an Airese dependency;
- advanced analytics, configurable dashboards or feature flags;
- multi-country rollout;
- a general-purpose EMR;
- broad administrator tooling beyond what is necessary to provision pilot users and support the workflow.
These capabilities should be reconsidered only after the referral-to-result workflow and one real import path have been proven.
4. Users and permissions
Referring clinician
- Creates and submits referrals.
- Sees referrals they created or patients explicitly assigned to them.
- Selects from TAS-provided sleep-test availability.
- Tracks referral status.
- Views and downloads the final source report.
- Acknowledges that the result has been reviewed.
TAS operations
- Sees referrals submitted to TAS.
- Requests missing information.
- Confirms, changes or cancels a TAS appointment.
- Records completion of the sleep test.
- Uploads the source result and enters the agreed structured result fields.
- Publishes the result to the referring clinician.
TAS pilot administrator
- Invites and disables pilot users.
- Assigns users to a clinic and role.
- Reviews the audit trail and resolves access problems.
The pilot administrator is a support role, not a reason to build a full admin product.
5. Core workflow
A. Referral
- The clinician signs in.
- The clinician starts a new referral.
- Atenvia pre-fills the clinician and clinic from the authenticated account.
- The clinician enters the minimum patient and referral information.
- The clinician attests that the patient has been informed and that the referral may be processed by TAS.
- The clinician selects an available TAS sleep-test slot.
- Atenvia shows a final summary before submission.
- Submission creates a referral ID and records an audit event.
B. Fulfilment
- TAS operations receives the submitted referral.
- TAS either confirms it, requests information, proposes a replacement slot or cancels it with a reason.
- Atenvia records each status change and makes it visible to the clinician.
- TAS marks the test completed after the real-world appointment.
C. Result return
- TAS uploads the original test-result PDF.
- TAS enters only the structured fields agreed during discovery, with the source report remaining authoritative.
- A second TAS user reviews the result package if the clinic requires a four-eyes step.
- TAS publishes the result.
- The clinician receives an in-product notification and, if approved for the pilot, an email containing no patient health data.
- The clinician signs in, views or downloads the report, and acknowledges review.
- Atenvia records publication, access, download and acknowledgement events.
6. Referral states
| State | Meaning | Next normal action |
|---|---|---|
| Draft | Not submitted; visible only to the clinician | Submit or discard |
| Submitted | Received by TAS but not confirmed | TAS reviews |
| Needs information | TAS cannot proceed | Clinician supplies missing information |
| Scheduled | TAS slot confirmed | Attend test |
| Test completed | Test occurred; result not yet published | TAS prepares result |
| Result ready | Result published to the clinician | Clinician reviews and acknowledges |
| Closed | Result acknowledged or case administratively closed | None |
| Cancelled | Referral will not proceed; reason required | Create a new referral if needed |
State changes must be validated server-side. History is append-only even when the current state changes.
7. Minimum data model
Organisation and user
- organisation ID and clinic name;
- user ID, verified email, display name and role;
- user status and last successful sign-in.
Patient and referral
- internal patient ID;
- patient name and the minimum identifiers TAS needs to match the appointment and result;
- contact details only if TAS operations requires them;
- preferred contact language if operationally required;
- referral ID, referring organisation and referring clinician;
- referral reason and relevant clinical context as agreed with the pilot clinic;
- consent/information attestation, actor and timestamp;
- created, updated and submitted timestamps.
Appointment
- TAS location and sleep-test type;
- slot ID, start time, timezone and status;
- confirmation, reschedule or cancellation reason;
- source of capacity data and last refresh time.
Result
- source PDF, immutable version and checksum;
- test date and publishing state;
- small set of source-derived structured fields;
- uploader, reviewer and publisher IDs with timestamps;
- clinician acknowledgement timestamp.
Audit event
- actor, organisation, action, target type and target ID;
- timestamp, outcome and request correlation ID;
- enough context to investigate access without copying clinical content into the log.
The discovery session must decide the exact minimum patient identifiers, referral fields and structured result fields before schema lock.
8. Access and privacy requirements
- Authentication and authorisation are enforced by the server, deny by default.
- Referring clinicians cannot list, search, open or infer the existence of another clinician’s patients unless explicitly assigned.
- TAS operations can access only the records required for TAS fulfilment.
- Every patient-record view, download and mutation is audited.
- Identifiable patient data is stored and processed in the approved region; the hosting decision requires stakeholder and privacy review before real data is used.
- Data is encrypted in transit and at rest; report downloads use short-lived authorised access.
- Production patient information never enters analytics, session replay, logs, error messages or non-production environments.
- Email notifications contain a referral ID or neutral prompt, not patient identity, diagnosis or result data.
- Pilot users can be disabled immediately and active sessions revoked.
- Retention, deletion, correction and breach-response rules must be approved before the controlled pilot.
This section is a product baseline, not legal certification. The DPO/legal owner must confirm the applicable Singapore requirements and TAS/Easmed data-controller roles.
9. Capacity and result-source boundaries
TAS capacity
The product shows only TAS-controlled sleep-test capacity. The first implementation may use an operations-maintained schedule or a narrow adapter to the current scheduling source. It must not become a generic calendar platform.
Double-booking must be prevented by a server-side reservation or transactional confirmation. A slot shown as available is not guaranteed until submission succeeds.
Result source
The first result path is manual PDF upload by TAS operations. The uploaded report is the authoritative source. Structured fields are for finding and summarising the result, not replacing it.
The first automated integration should replace one proven manual step. Vendor selection follows evidence about access, volume and clinic value; it does not precede workflow validation.
10. UX brief
Feature summary
A focused clinical operations workflow used by referring clinicians and TAS staff during a time-sensitive patient handoff. It should make current status, next owner and outstanding action unmistakable.
Primary user action
The clinician completes a valid referral and secures a TAS slot; later, the same record makes the result immediately retrievable.
Provisional design direction
Calm, clinical and operational. Light-first for daytime clinic use, with dense but readable information, restrained status colour, visible provenance and no decorative clinical theatre. This direction requires stakeholder confirmation before visual design is locked.
Layout strategy
- Use a task-oriented referral list as the home surface, ordered by required action rather than dashboard metrics.
- Keep one patient/referral record as the shared workspace for details, appointment, result and history.
- Show status, next action, owner and last update at the top of the record.
- Use a step flow for referral creation, with a persistent review summary and explicit final submission.
- Keep the source report and provenance adjacent to structured result fields.
- Use tables or compact lists for operational volume; avoid card grids and modal-heavy flows.
Required interface states
- first-time clinician with no referrals;
- populated referral list;
- new referral draft;
- slot loading, stale or no longer available;
- submitted successfully;
- missing information requested;
- scheduled and rescheduled;
- test completed with result pending;
- result ready, unread, viewed and acknowledged;
- cancelled;
- upload interrupted or rejected;
- unauthorised or expired session;
- temporary service failure with safe retry;
- record changed by another user.
Interaction principles
- Autosave drafts only after the user has authenticated; always show save state.
- Confirm submission because it creates an external operational commitment.
- Require a reason for reschedule, cancellation and result withdrawal.
- Do not optimistically confirm a slot; wait for the server reservation.
- Preserve entered referral data if slot confirmation fails.
- Never use colour alone for status or severity.
- Support keyboard operation and WCAG 2.2 AA as the implementation baseline.
Recommended implementation references
- interaction design for the referral form, save state and concurrent edits;
- spatial design for the record workspace and operational lists;
- UX writing for consent, missing-information and result-ready messaging;
- responsive design for tablet use during clinical operations;
- colour and contrast for status semantics.
11. Acceptance criteria
Happy path
- A provisioned clinician can sign in, submit the required referral fields, reserve an available TAS slot and receive a referral ID.
- TAS operations sees the same referral without manual re-entry and can confirm the appointment.
- TAS can upload and publish a source report.
- The assigned clinician can view and download the report and acknowledge it.
- The audit trail contains every required access and state transition.
Isolation and failure
- A clinician cannot discover or access another clinician’s patient through lists, search, guessed IDs, direct URLs or API requests.
- Two users cannot confirm the same slot.
- A failed upload or publish operation does not create a partial result-ready state.
- Removing a user’s access blocks new requests and revokes active sessions within the agreed interval.
- No patient health data appears in analytics or operational logs.
Usability
- A clinician unfamiliar with Atenvia completes a referral and booking without facilitator intervention.
- A returning clinician can identify which referrals require action from the list alone.
- A clinician can find a published result from the referral list without knowing where TAS stored the source file.
12. Proposed UAT evidence
Before controlled pilot approval, retain:
- participant role and clinic type, without unnecessary personal information;
- test environment and build identifier;
- scenario result and task-completion time;
- errors, assistance required and abandonment reason;
- access-control and audit-log evidence for the same run;
- issues raised, owner and disposition;
- signed product, operations, clinical and privacy approval for pilot entry.
Proposed targets for stakeholder confirmation:
- 100% completion of the core referral-to-result scenario by pilot participants;
- no phone call or off-platform re-entry on the happy path;
- median referral submission time of three minutes or less once patient details are available;
- median result retrieval time of one minute or less from sign-in;
- zero cross-clinic or cross-clinician access failures;
- 100% audit coverage for defined sensitive events.
13. Success measures after pilot
- referral completion rate;
- time from referral start to submitted booking;
- proportion of referrals requiring off-platform clarification;
- time from test completion to result publication;
- result-view and acknowledgement rate;
- support contacts per referral;
- clinician-reported effort compared with the current process;
- repeat referrals from participating clinicians.
Avoid aggregate dashboard vanity metrics until the underlying events are reliable and the pilot volume makes them meaningful.
14. Delivery slices and gates
Slice 0: workflow validation
- Walk one real clinic and TAS operations through the current process.
- Confirm roles, minimum fields, handoffs, capacity source and result source.
- Test a low-fidelity referral-to-result prototype with synthetic patients.
Gate: the clinic and TAS agree the flow reflects reality and identify the step whose removal creates value.
Slice 1: secure staging vertical
- Implement authenticated clinician and TAS-operations roles.
- Implement server-scoped referrals, TAS slots, statuses, report upload and audit events.
- Use synthetic data only.
Gate: automated isolation tests and moderated end-to-end UAT pass.
Slice 2: controlled clinic pilot
- Complete privacy, operational and security readiness checks.
- Provision a small named pilot group.
- Run the real workflow with support and explicit incident ownership.
Gate: no critical safety/access issue, operational service level is sustainable, and clinicians demonstrate reduced coordination effort.
Slice 3: one integration proof
- Select the highest-value source using actual pilot friction and confirmed vendor access.
- Automate one inbound step while retaining source provenance and the manual fallback.
Gate: imported data reconciles to the right patient, failures are observable and recoverable, and the integration reduces measured effort.
CPAP longitudinal monitoring is sequenced after this gate.
15. Reuse from the current prototype
Potentially reusable after review:
- clinician vocabulary and the five-stage patient-journey hypothesis;
- patient-list, patient-detail and report information hierarchy;
- design tokens and Atenvia brand assets;
- vendor-specific threshold research, after clinical validation;
- PDF presentation patterns, after the source and audit model is established.
Do not inherit by default:
- the monolithic application structure;
- mock patient and user models;
- fixed dates or generated clinical data;
- client-side access checks;
- analytics implementation;
- dashboard-first navigation;
- deployment, CI or infrastructure scaffolding;
- the June roadmap’s admin-and-four-vendor critical path.
16. Open decisions
These decisions are required before the relevant gate, not before discovery begins:
- Which clinic and clinician roles participate in the first workflow walkthrough and UAT?
- Who owns and updates TAS sleep-test capacity today, and what system or document is authoritative?
- Which minimum identifiers and referral fields does TAS need to fulfil a booking safely?
- Which structured result fields, if any, should appear beside the authoritative PDF?
- Does result publication require a second TAS reviewer?
- Which notifications are acceptable, and may email be used for a neutral result-ready prompt?
- What is the approved data-hosting region and the TAS/Easmed controller/processor model?
- What retention, deletion and correction rules apply during the pilot?
- What service level should TAS commit to from test completion to result publication?
- What three words should define Atenvia’s clinician-facing personality? The current draft assumes calm, clinical and operational.
17. Confirmation checklist
The brief is ready to baseline when Product, TAS Operations, Clinical, Privacy/Security and the pilot clinic agree that:
- referral-to-result is the first outcome;
- manual PDF result return is acceptable for the first release;
- CPAP monitoring and vendor integrations remain deferred;
- the listed roles and state transitions match the real workflow;
- the data collected is the minimum required;
- the proposed UAT evidence demonstrates readiness;
- the provisional design direction is acceptable or has been replaced.